Advantages of using the ANSI/ASHRAE tracer gas test method vs. the ANSI/AIHA. Z face velocity test method for the. expressed in feet per minute (fpm) or meter per second (m/s) (ANSI/ASHRAE necessarily involving the use of a bench or a table (ANSI/ASHRAE , ). SEFA (Scientific Equipment Furniture. Association), formerly SAMA (Scientific. Apparatus Manufacturer Association). (recommended practices). ▫ ASHRAE .
Author: | Kegul Grokazahn |
Country: | Norway |
Language: | English (Spanish) |
Genre: | Art |
Published (Last): | 21 March 2010 |
Pages: | 213 |
PDF File Size: | 14.10 Mb |
ePub File Size: | 11.83 Mb |
ISBN: | 607-3-54083-974-7 |
Downloads: | 65053 |
Price: | Free* [*Free Regsitration Required] |
Uploader: | Ganos |
Interpretations For Standard 110-1995
Hitchings DT, Maupins K. Application of non-dispersive infrared NDIR spectroscopy to the measurement of atmospheric trace gases. A new method for quantitative, in-use testing of laboratory fume hoods. Evaluation of laoratory hoods in Tehran Water and Aashrae water Co. SF 6 is extremely hostile to environment and expensive. Chemical Health and Safety.
Skip to main content Skip to main navigation menu Skip to site footer. Design, Construction, Maintenance, Health and Safety.
In this test, sulfur hexafluoride SF6 is applied as a tracer gas to quantitatively evaluate the performance of laboratory hoods. J Occup Environ Hyg ; 11 1: American National Standard for Laboratory Ventilation.
Ashrae Std Testing Laboratory Fume Hoods
Maupins K, Hitchings DT. The environmentally hostile characteristics of SF6 as well as its cost are the major concerns. Exploring the use of less environmentally damaging gases for use in tracer gas testing. Significance of face velocity fluctuation in relation to laboratory fume hood performance. Ann OccupHyg ; 51 2: Air flow was visualized through injecting low and high volume of smokes at 18 tests.
Lawrence Berkeley National Laboratory. Vol 6 No 1 The application of ASHRAE hood performance test with smaller volume of tracer sulfur hexafluoride gas is not recommended.
Tracer performance testing of installed fume hoods: Am Ind Hyg Assoc ;59 2: Dale T, Maupins K. The performance of a laboratory hood was evaluated using ASHRAE standard method at three different ventilation capacity as well as three different volumetric flow rates of injected SF 6 while a mannequin was located at the front of hood.
interpretations-for-standard
UC Lab Ashare Workgroup. Choosing less environmentally damaging gases for fume hood tracer gas testing. The concentration of tracer gases was measured using direct reading instruments.
Meanwhile, the exposure of a mannequin stationed at the front of hood was measured. Taylor S, Initiative TC.
Ind health ;48 1: In present work, the possibility of conducting this method of hood performance test with less volume of SF 6 was investigated. Laboratory fume hood performance. Face velocity was measured times using a thermal anemometer TA-2 model.
Linear regression of the ashraae was used to consider the substitution of ethylene with SF6. Industrial Ventilation a manual of practice for designe 27th ed.
Laboratory hood, Tracer gas, Ethylene, SF6. Islamic Azad university; The occupational exposure of the proposed hood operator to SF6 and ethylene were 4.