IEEE Recommended Practice For Testing Insulation Resistance Of Electric Machinery Defines a recommended procedure for measuring insulation. The Institute of Electrical and Electronics Engineers (IEEE) standard for insulation resistance testing of motor and generator windings that was published in Content Description. Revision Standard – Active. The dc voltage tests procedures for the measurement of the insulation resistance and polarization index of.

Author: Faek Malalkis
Country: Serbia
Language: English (Spanish)
Genre: Travel
Published (Last): 1 June 2014
Pages: 357
PDF File Size: 13.91 Mb
ePub File Size: 17.93 Mb
ISBN: 570-2-28057-745-7
Downloads: 5072
Price: Free* [*Free Regsitration Required]
Uploader: Akisida

Enter your account email address request ieee password reset: The dc voltage tests procedures for the measurement of the insulation resistance and polarization index of insulated stator, and rotor windings and how to interpret the results are described in iewe recommended practice.

The ground insulation certainly can be weak with conduction current flowing through the ieer to ground, but this ieeee often dwarfed by the surface currents. If you like to setup a quick demo, let us know at support madcad.

C, and taken at a specified time t from start of voltage application. Are you sure you want to empty the cart? Copyright Compu-tecture, Inc. By definition, the insulation resistance is the quotient of the applied direct voltage across the insulation divided by the total resultant current at a given time. It is recommended that subsequent ac high-potential testing not be conducted until the winding is fully discharged. The insulation resistance of a rotating machine winding is a function of the type and condition of the insulating materials used, as well as their application technique.

  ENTABLILLADO DE FRACTURAS PDF

IEEE 43-2013 PDF

Sustainable Development Goals and standardisation, how do they connect? There were no books found for the applied search filters. The dc voltage tests procedures for the measurement ieee the insulation resistance and polarization index of insulated stator, and rotor windings and how to interpret the results are described in this recommended practice. There are ieee temperature compensation formulas, and ieee one above may be the most conservative. These can only be obtained from the manufacturer of the motor.

Subscribe on standards — Read more. The difference in insulation resistance is high because of how resistance is calculated.

Who knows, maybe no better at all? This current is usually zero if the motor is new or undamaged. You can change your cookie settings through your browser. Users will often go directly to a Hipot ieee No items in cart. The IEEE Brand Identity Toolkit explains the basic usage rules for all corporate identity elements and how to utilize them to create a powerful and consistent communications pieces. Are you sure you want to empty the cart? There were no books found for the applied search filters.

The ground insulation certainly can be weak with conduction current flowing through ieeee insulation to ground, but this is often dwarfed by the surface currents. A reversible current of comparatively high magnitude and short duration, which decays exponentially with time of voltage application, and which depends on the internal resistance of the measuring instrument and the geometric capacitance of the winding.

When IR is tracked over time, resistance values must be temperature compensated and the temperature must be above the dew point for comparisons of results to make sense.

  HANDE ALTAYLI KAHPERENGI PDF

What’s new in the IEEE 43 insulation resistance testing standard? | EASA

After the applied direct voltage is removed, a suitable discharge circuit should be provided see Clause 4. Ieee IEEE standards that include information on insulation resistance measurement are listed in Clause 2.

They were placed on your computer when you launched this website.

Land Use and Development. Most insulation testers will do this automatically if the winding temperature is entered in the tester.

I G — Conductance current: Modern types of filmcoated wire, as well as epoxy-mica or polyester-mica insulated stator windings, may approach a constant value of insulation resistance in 4 min iee less. The surface leakage current may be significantly higher on large turbine generator rotors and dc machines, which have relatively exposed creepage surfaces. Get a Quote Careers Exhibitions.

The safety measures described are by no means exclusive. For large machines with high capacitance, the inrush current can ieew high. A current that is constant in time, that passes through the bulk insulation from the grounded surface to the high-voltage conductor, and that depends on the type of bonding material used in the insulation system. The measured insulation resistance will usually rapidly increase when the voltage is first applied, and then gradually approach a relatively constant value as time elapses see Figure 4.